Installation, cont’d
MediaLink Controllers • Installation2-10
Extron switcher control connections
6
Contact closure Tally Out(put) connector — To effectively add more A/V
inputs to a projector, you aren’t limited to using a MediaLink switcher. If
desired, attach an Extron switcher that accepts contact closure control to this
3.5 mm, 6 pole direct insertion captive screw connector. Each pin corresponds
to a switcher front panel button. When a tally pin is selected, the pin changes
from a high (5V) to a low (0V) state. This momentary high-to-low change can
be used to trigger switching on various contact closure controllable Extron
switchers.
Wire the connector as shown here.
MLC 206 Contact Closure Control
1
62345
Tally Out
MLC
MLS/Power
port
AB
MLS
/
Power
MLC
IR
/
IRCM
port
ABCD
IR
/
RCM
or
Input 2
Input 1
Input 3
Input 4
Input 5
Input 6
To any
contact closure-
controllable
Extron switcher
6
5
4
3
2
1
SW 6 AR MX
123456
Connect the switcher's
contact closure
ground pin to a
ground on the MLC.
You must connect the ground pin of the switcher’s connector to a ground
connection on the MLC.
Only Extron switchers can be slaved to the MLC via this tally output contact
closure connector.
7
MLS/Power connector — Connect a cable between this 3.5 mm, 4-pole direct
insertion captive screw connector and an optional Extron MLS switcher for
RS-232 control of the switcher and to provide power from the switcher to the
MLC. See the following diagram. With Extron Comm-Link cable, the
switcher and controller can be up to 250 feet (76.2 m) apart.
The commands issued from this port are standard Extron SIS™ commands,
and they follow the Extron switcher protocol (9600 baud rate, 8-bit, 1 stop bit,
no parity). The commands sent via the MLS/Power connector are fixed and
cannot be altered. See page 3-3 for additional details.
MLC/IR
ABC
MLS 506MA Rear Panel
Connecting an MLC 206 to a MediaLink Switcher
100-240V 0.2A 50/60 Hz
.5A MAX
INPUT 1
VIDEO
Y
C
R-Y
B-Y
YUV
Y
R-Y
B-Y
VIDEO
S-VIDEO
Y
C
INPUT 2
VIDEO
Y
C
R-Y
B-Y
INPUT 3
VIDEO
Y
C
R-Y
B-Y
INPUT 4
RH/
HV
G
V
B
INPUT 5
RH/
HV
G
V
B
INPUT 6
RH/
HV
G
V
B
RGB
RH/
HV
G
V
B
4 ohm
MONO AMPLIFIED OUTPUT
COMM 8 ohm 70V
LR LR LR
LR
AUX/MIXEFFECTS
LR
SEND
LR
RETURN
MLC/IR RS232
CONTACT CLOSURE
ABC
AUDIO OUT
FIXED VARIABLE
LRLR
L LRR LR
MediaLink
Switcher
rear panel
MLC/IR port
NOTE
The switcher provides
power to the controller.
MLC
MLS/Power
port
NOTE If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
ABCDE ABC
IR
Display/Source Control
Extron Switcher Control
Relays IR/RCM
RS-232
DE ABC ABD
1A 1B 2A 2B 3A 3B
123456
Tally Out
MLS
/Power
33-644-01 A
07 01
Printed in the
USA
Ground ( )
+12VDC
Transmit (Tx)
B
Receive (Rx)
A
250 feet (76.2 m) maximum
AB
MLS
/
Power
Transmit (Tx)
Receive (Rx)
+12VDC
Ground ( )
B
A
MLC 206 Bottom Panel