Extron electronics ISS 408 Manuale Utente Pagina 50

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 133
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 49
2.22 Knox64CM
Controls modular routing switchers with up to 99 inputs and outputs.
2.22.1 Supported Devices
This Control Module is for use with video switchers manufacturered by
Knox Video Technologies. The following models have been tested:
Chameleon
Chameleon64
Chameleon64i
RS 16x16
RSII Series
2.22.2 Physical Connections
You will need an available RS-232 port, and an appropriate cable. The device
end of the cable needs a male DE-9 connector.
FIGURE 2.19:
RS-232 straight
through cable
Server
Server
9 pin Female
9 pin Female
2
RxD
3
TxD
5
GND
Device
Device
9 pin Male
9 pin Male
2
RxD
3
TxD
5
GND
2.22.3 Serial Port settings
Consult your device’s documentation for instructions on how to setup its
serial port. Cablecast uses the following settings:
Baud Rate : 9600 baud
Stop Bits : One
Byte Size : 8 bits
Parity : None
Flow Control : None
2.22.4 Location Settings: I/O: Control Module Sets Settings
Create an entry for this Control Module in the Location Settings: I/O: Con-
Location Settings: I/O:
Control Module Sets
trol Module Sets menu. Enter the following information into the fields:
CMS Name : A descriptive name, such as “Router”.
Control Module : Select the corresponding Host and Control Module
Example: localhost : Knox64CM
50
Vedere la pagina 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 132 133

Commenti su questo manuale