Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Presets
User presets (DVI, RGB, and YUV inputs only)
Recall preset
1*
X2%
. 1 Rpr
X2% ]
Recalls user preset
X2%
for the
selected input.
Save preset
1*
X2%
, 1 Spr
X2% ]
Saves user preset
X2%
for the
selected input.
User preset name
NOTE: To clear a user preset name, a single space character should be entered for
X1$
. This action resets the
user name back to the default setting.
Write name
E
1*
X2%
*
X1$
PNAM
}
Pnam1*
X2%
*
X1$ ]
Set the name (
X1$
) for
user preset
X6#
.
View name
E
1*
X2%
PNAM
}
X1$ ]
View the name of user preset
X6#
.
Input presets (RGB and YUV inputs only)
Recall preset
2*
X2^
. 2 Rpr
X2^ ]
Recalls input preset
X2^
.
Save preset
2*
X2^
, 2 Spr
X2^ ]
Saves input parameters to
preset
X2^
.
Input preset name
NOTE: To clear an input preset name, a single space character should be entered for
X1$
. This action resets
the input name back to the default setting.
Write name
E
2*
X2^
*
X1$
PNAM
}
Pnam2*
X2^
*
X1$ ]
Set the name (
X1$
) for input
preset
X2^
.
View name
E
2*
X2^
PNAM
}
X1$ ]
View the name of input preset
X2^
.
Streaming presets
Recall preset
3*1*
X6#
. 3 Rpr
X6# ]
Recalls streaming preset
X6#
for the selected input.
Save preset
3*
X6#
, 3 Spr
X6# ]
Saves streaming preset
X6#
for
the selected input.
Streaming preset name
NOTE: To clear a streaming preset name, a single space character should be entered for
X1$
. This action
resets the preset name back to the default setting.
Write name
E
3*
X6#
*
X1$
PNAM
}
Pnam3*
X6#
*
X1$ ]
Set the name (
X1$
) for
streaming preset
X6#
.
View name
E
3*
X6#
PNAM
}
X1$ ]
View the name of streaming
preset
X6#
.
NOTES:
X1$ = Text label / Preset name Up to 16 characters
X2% = User presets 1 through 16
X2^ = Input presets 1 through 128
X6# = Streaming presets 1 through 16 (default = 1)