28 SMX System MultiMatrix Switcher • SIS Programming Guide
Command ASCII Command
(host to switcher)
Response
(switcher to host)
Additional Description
EDID (Extended Display Identication Data) Commands
Assign EDID data to input
E
A
X3)
*
X!
*
X3@
EDID}
X3)
EdidA
X!
*
X3@
]
Assign EDID data to all inputs
E
A
X3)
*
X3@
*EDID}
X3)
EdidA00*
X3@
]
Save output 1 EDID data to user
space
E
S
X3)
*
X3@
EDID}
X3)
EdidS
X3@
] Applies only where
X3@
= 37 to 40.
View EDID data assignment
E
A
X3)
*
X!
EDID}
X3@
]
X3)
EdidA
X!
*
X3@
]
Verbose mode 2 or 3
Export EDID file data
E
E
X3)
*
X3@
EDID}
X6)
]
X3)
EdidE
X3@
*
X6)
]
Verbose mode 2 or 3
Import EDID file data to user file
location
E
I
X3)
*
X3@
EDID}
X6) X3)
EdidI
X3@
] Applies only where
X3@
= 37 to 40
NOTE: For the EDID table, see page 21 or refer to the online SMX User Guide.
NOTES: X! = Input number 01 - <maximum number of inputs>
X3) = Slot address 01 -10
X3@ = EDID reference file for DDC data 00 - 40, where 15 = default, 1 - 8 = stored from connected EDID monitors as
reference, 9 - 36 = factory fixed rates, 37 - 40 = user definable
X6) = EDID file data block 128 bytes of binary data