Extron-electronics Priority Page Sensor Kit Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Hardware Extron-electronics Priority Page Sensor Kit. Extron Electronics Priority Page Sensor Kit User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 1
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Installation Procedure
N
Follow all local fire and safety code requirements for installation and anchoring. Install the Priority Page Sensor in a UL-compliant
junction box with a cover to meet plenum rating requirements.
For detailed installation instructions, refer to the PoleVault Installation Guide (see www.extron.com)
The sensor must be placed close to and in series with the speaker.
1. Open the top of the Priority Page Sensor (see the figure at right).
Priority Page Sensor Kit Installation Instructions
L R
L R
L
R
AUX AUDIO
INPUT 5
LINE OUT
VL RECEIVER
PAGING
SENSOR
DO NOT GROUND
OR SHORT
SPEAKER OUTPUTS
1B RGB
1A RGB
2B RGB
2A RGB
3B RGB
/VIDEO
4B RGB
/VIDEO
3A RGB 4A RGB
I
N
P
U
T
S
RS-232 MLC/IR
DC VOL
2/4/8 Ohms
AMPLIFIED AUDIO OUT
VOL/MUTE
TxRx IR 12V
10V
POWER
PLENUM RATED UL 2043
US
LISTED
17TT
AUDIO/VIDEO
APPARATUS
®
RGB
VIDEO
OUTPUTS
CONTROL
N15779
12V
5A MAX
Ceiling Mounted
Paging Speaker
Paging System
Priority
Page
Sensor
ClassroomAdmin Building
To Classroom
Paging Speakers
Sensor
Output
Paging
Sensor
Input
PoleVault Twisted
Pair Switcher
Extron
SI 26
Surface Mount
Speakers
The Priority Page Sensor kit is designed for use with all PoleVault
®
switchers that have a paging sensor input. When the Priority Page
Sensor senses a PA system broadcast, it sends a signal to mute the
switcher’s program audio output for the duration of the PA broadcast.
The parts included with the kit include:
Priority Page Sensor•
35’ (10.6 m) plenum-rated shielded twisted pair cable•
UL-compliant junction box with cable clamp and cover.•
The Priority Page Sensor is plenum rated but must be
installed in a UL‑compliant junction box with a cover to
meet the plenum rating requirement. All cables to and from
the sensor must also be plenum rated.
N
The Priority Page Sensor works with 25 V or 70 V and
4/8 ohm PA systems. It was not designed for, and may
not work properly with two-way intercoms, or systems
that are IP-based or use digital clocks.
Priority Page Sensor Kit Overview
2. Remove the outer protective jacket from the speaker cable to expose the
two individual wires from the position of the sensor to the speaker. Do
not remove the inner protective jackets that cover the individual wires.
3. If a junction box is being used in a plenum space, attach the cable clamp
and ensure the sensor and all wires fit inside the box, as shown in the
figure below, right. All cables leaving the box must be plenum rated.
4. Loop (only) one of the exposed speaker leads tightly around the top (open)
part of the sensor (as shown at right). Either speaker wire will work. Leave the
other speaker wire connected directly to the speaker. Polarity need not be observed.
•Fora25Vor70Vsystem—wrap5to8loops.
•Fora4/8ohmsystem—wrap2to4loops.
5. Close and latch the top of the Priority Page Sensor.
6. Connectthebarewireendofthesuppliedbluesensorcabletothe2-polecaptivescrewconnectoronthe
Priority Page Sensor, passing it into the junction box, if necessary. Polarity need not be observed.
7. Tighten the cable clamp and secure the lid to the junction box.
8. Route the connector end of the blue sensor cable to the PVS switcher, and plug it into the Paging Sensor input.
9. Enable the switcher’s paging sensor port, using Global Configurator or the MediaLink Switchers (MLS) and
PoleVault Switchers (PVS) control software, available at www.extron.com
Testing and Adjustment Procedure
1. Turn the program audio on.
2. Speak into the PA system microphone. The program audio is muted while the PA system broadcast
occurs, and restored when the PA broadcast ends.
3. If program audio is not muted during a PA broadcast, turn the Paging Sensitivity adjustment on the
PoleVault switcher clockwise.
4. If program audio is muted without a page occurring, turn the Paging Sensitivity adjustment on the PoleVault
switcher counterclockwise.
Ceiling Mounted
Paging Speaker
Priority
Page
Sensor
Strip plenum jacket from
speaker cable to reveal
two speaker wires.
Speaker Cable with
Plenum Jacket Intact
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800
+971.4.2991880 FAX
68-1489-01 B
03 09
N
To prevent the program audio from being
restored prematurely due to a pause by the
announcer, you can set a time delay from
1 to 8 seconds via the switchers RS-232
interface. See the switchers Users Manual.
Vedere la pagina 0
1

Sommario

Pagina 1 - Installation Procedure

Installation ProcedureN Follow all local fire and safety code requirements for installation and anchoring. Install the Priority Page Sensor in a UL-c

Commenti su questo manuale

Nessun commento

Küppersbusch IG6504.1E-CN podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Nie Küppersbusch IG6504.1E-CN.
Dostarczamy 3 pdf podręczników Küppersbusch IG6504.1E-CN do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Nie Küppersbusch

Modele Rodzaj dokumentu
IGU1390-1 Instrukcja Użytkownika      Küppersbusch IGU1390-1 Handleiding [el] , 40 strony
FKE237-5 Instrukcja Użytkownika      Küppersbusch FKE237-5 Handleiding, 18 strony
IGV657.1 Instrukcja Użytkownika   Küppersbusch IGV657.1 Handleiding, 20 strony
IKEF2580-0 Instrukcja Użytkownika    Küppersbusch IKEF2580-0 Handleiding, 36 strony
IKE328-5-2T Instrukcja Użytkownika      Küppersbusch IKE328-5-2T Handleiding, 18 strony
IKE3390-2 Instrukcja Użytkownika      Küppersbusch IKE3390-2 User Manual, 56 strony
IKEF3084Z3 Instrukcja Użytkownika     Küppersbusch IKEF3084Z3 Εγχειρίδιο χρήστη, 80 strony
ITE239-0CN Instrukcja Użytkownika    Küppersbusch ITE239-0CN 用户手册, 16 strony
IGV458.3 Instrukcja Użytkownika   Küppersbusch IGV458.3 User Manual, 28 strony
IKE1780-0E Instrukcja Użytkownika     Küppersbusch IKE1780-0E User Manual [bg] [hr] [sq] , 40 strony
IKE320-2-2 Instrukcja Użytkownika      Küppersbusch IKE320-2-2 Handleiding [ru] [ua] , 36 strony
IKE326032T Instrukcja Użytkownika      Küppersbusch IKE326032T Kasutusjuhend, 56 strony
IKE197-9 Instrukcja Użytkownika    Küppersbusch IKE197-9 Manuale utente, 28 strony
FKE237-4 Instrukcja Użytkownika      Küppersbusch FKE237-4 Handleiding, 16 strony
IKE198-0 Instrukcja Użytkownika    Küppersbusch IKE198-0 Manuale utente, 20 strony
IKE259012T Instrukcja Użytkownika     Küppersbusch IKE259012T Manuel utilisateur, 60 strony
IKEF329-0 Instrukcja Użytkownika     Küppersbusch IKEF329-0 User Manual [en] [ko] , 36 strony
IKEF2680-0 Instrukcja Użytkownika    Küppersbusch IKEF2680-0 Handleiding, 32 strony
IKE197-6 Instrukcja Użytkownika    Küppersbusch IKE197-6 Handleiding [en] , 10 strony
JKG7463 Instrukcja Użytkownika      Küppersbusch JKG7463 Handleiding [de] [es] [fr] [it] , 18 strony